华体会平台官网

The Quick and Easy M-Bus to Modbus and BACnet Solution.

The EZ Gateway M-Bus to Modbus and BACnet is an easy to use, high-performance building and industrial automation protocol gateway for integrators to interface M-Bus products to Modbus and BACnet management systems in commercial buildings, campuses and industrial facilities over Modbus RTU, Modbus TCP/IP, BACnet MS/TP or BACnet/IP protocols. M-Bus products encompass a wide range of applications such as energy, gas, heating, water, VFD drives and PLCs. M-BUS to Modbus and BACnet protocol translations include:

  • M-Bus to Modbus
  • M-Bus to Modbus TCP/IP
  • M-Bus to BACnet/IP
  • M-Bus to BACnet MS/TP
This product is protected by FieldSafe.

Presentation:

With the EZ Gateway M-Bus to Modbus & BACnet, the integrator or contractor does not need to be a protocol expert, and can minimize configuration and commissioning time, while also reducing ongoing operating and maintenance costs.

The EZ Gateway M-Bus to Modbus & BACnet combines field-hardened M-Bus, Modbus and BACnet protocol drivers with an easy to use configuration interface that, once configured, allows M-Bus devices to be presented as virtual BACnet devices which simplifies commissioning, configuration and troubleshooting. The intuitive web-based interface allows configurations to be built in the field or in the office. Additionally, the configuration profiles can be downloaded and then uploaded to other FieldServer M-Bus applications, simplifying the commissioning and integration process on repeatable applications.

1. M-BUS INTEROPERABILITY

  • M-Bus Explorer discovers all M-Bus devices in the network, shows the manufacturer details as well as available points, and offers one-click profile generation
  • Profile Loader enables efficient profile editing, exporting and importing
  • Up to 64 slave devices (max device count based on model)
  • Communication between devices with different baud rates at the same time
  • Virtual nodes allow each M-Bus device connected to a single EZ Gateway to be seen as a separate device on the BACnet network
2. BACNET COV
  • Use the Change of Value (CoV) setting to reduce the amount of BACnet data overhead to allow network traffic to be less congested by transmitting data only when detecting an M-Bus device status change
3. REMOTE ACCESS AND SUPPORT
  • All FieldServer gateways come with Remote Access support.  Once registerd to the MSA Grid, use the Remote Access capability to attach to the FieldServer gateway to monitor, maintain and troubleshoot installed equipment
4. BACNET BBMD SERVER SUPPORT
  • For connecting to remote BACnet networks
5. REMOTE DIAGNOSTICS
  • Diagnostics of the devices connected to the network is available via Web Interface
6. MSA GRID SUPPORT
  • Register your EZ Gateway to the MSA Grid interface for remote access to local applications, configuration, and device management

Model Numbers   

  • FS-EZ1-MBUS-MOD-BAC: 16 slave devices
  • FS-EZ2-MBUS-MOD-BAC: 32 slave devices
  • FS-EZ3-MBUS-MOD-BAC: 64 slave devices

Power Requirements

  • 9-30V DC or 12-24V AC
  • Current draw @ 12V:
    • 1 Slave: 580 mA
    • 64 Slaves: 980 mA

Enclosure   

  • Dimensions: 4.5 x 2.9 x 1.6 in. (11.5 x 7.4 x 4.1 cm)
  • Weight: 0.4 lbs (0.2 Kg)

Environmental   

  • Operating Temperature: -40 to 75C (-40 to 167F))
  • Relative Humidity: 5-90% non-condensing

Other   

  • Configuration/Diagnostic utilities
  • Table, wall, or DIN rail mount

Communication   

  • Baud: 2400, 4800, 9600, 19200, 38400
  • Start Bit: 7, 8
  • Ethernet: 10/100 BaseT MDIX

 

技术许可如有变更,恕不另行通知。基于配置、部件号和/或国家的不同,技术许可可能有所差别。